Predicting Chinese children and youth's energy expenditure using ActiGraph accelerometers: a calibration and cross-validation study.

  • Published on December 2013

Purpose The purpose of this study was to develop and cross-validate an equation based on ActiGraph accelerometer GT3X output to predict children and youth's energy expenditure (EE) of physical activity (PA). Method Participants were 367 Chinese children and youth (179 boys and 188 girls, aged 9 to 17 years old) who wore 1 ActiGraph GT3...


Calibration and cross-validation of a wrist-worn Actigraph in young preschoolers.

  • Published on Jan.10, 2014

Objective To calibrate the Actigraph GT3X+ accelerometer for wrist-worn placement in young preschoolers by developing intensity thresholds for sedentary, low- and high-intensity physical activity. Furthermore, to cross-validate the developed thresholds in young preschoolers. Methods Actigraph GT3X+ was used to measure physical activity during structured activities and free play ...



Validity of the Acti4 software using ActiGraph GT3X+accelerometer for recording of arm and upper body inclination in simulated work tasks.

  • Published on Jan. 7, 2014

The validity of inclinometer measurements by ActiGraph GT3X+ (AG) accelerometer, when analysed with the Acti4 customised software, was examined by comparison of inclinometer measurements with a reference system (TrakStar) in a protocol with standardised arm movements and simulated working tasks. The sensors were placed at the upper arm (distal ...


Detection of physical activity types using triaxial accelerometers.

  • Published on January 2014

Background The aim of this study was to validate a triaxial accelerometer setup for identifying everyday physical activity types (ie, sitting, standing, walking, walking stairs, running, and cycling). Methods Seventeen subjects equipped with triaxial accelerometers (ActiGraph GT3X+) at the thigh and hip carried out a standardized test procedure including ...



Predicting Physical Activity Energy Expenditure in Manual Wheelchair Users

  • Published on Feb. 5, 2014

Purpose To assess the influence of anatomical placement of an accelerometer on physical activity energy expenditure (PAEE) prediction in manual wheelchair users. Methods Ten accelerometer units (Actigraph GT3X+) were attached to a multi-axis shaker table and subjected to a sinusoidal oscillation procedure to assess mechanical validity and reliability. Fifteen ...



Comparison of Pedometer and Accelerometer Derived Steps in Elderly Individuals With Parkinson’s Disease or Osteoporosis Under Free-Living Conditions.

  • Published on Dec. 4, 2013

Aim To compare self-reported pedometer steps with accelerometer steps under free-living conditions in individuals with Parkinson's disease (PD) or osteoporosis (OP). Methods Seventy-three individuals with PD and 71 individuals with OP wore a pedometer (Yamax LS2000) and an accelerometer (Actigraph GT1M/GT3X+) simultaneously for one week. Results Fifty-one individuals ...


Reliability and Validity of the Sedentary Behavior Questionnaire (SBQ) for Adults

  • Published on 2010

Background Sedentary behavior is related to obesity, but measures of sedentary behaviors are lacking for adults. The purpose of this study was to examine the reliability and validity of the Sedentary Behavior Questionnaire (SBQ) among overweight adults. Methods Participants were 49 adults for the 2 week test-retest reliability study (67% female, 53% white, mean ...